Axial-piston pump for reverse-osmosis systems. Parameters use the checked Danfoss 2024.06 data-sheet revision. Tabulated flow belongs to the stated speed and maximum table pressure, not any arbitrary duty point. Sound is measured on a motor-pump unit at maximum pressure and speed, at 1 m under EN ISO20361/EN ISO3744; it is not a noise guarantee for every installation. Pump, drive, coupling, filtration and supply scope are agreed separately.
Technical parameters
- Technical source revision
- AI274333290009en-000702 · 2024.06
- Table fluid temperature
- 2–50 °C; depends on NaCl
- Table ambient temperature
- 0–50 °C; see source qualification
- Inlet filtration, section 9.1
- 10 µm absolute; efficiency 99.98%; β10 ≥5000
- Integrated flushing valve
- Present in stated APP range
- Inlet/outlet on sheet 30
- M42 × 1.5; depth 17 mm
- Bleed connection
- G 1/4; hex key 6 mm
- DIN 6885 parallel key
- 10 × 8 × 45 mm
- Earth connection on sheet 30
- M8; depth 8 mm
- Thermal sensor on sheet 30
- M6; depth 8 mm
- Dimension line 337 on sheet 30
- 337 mm
Configurations and specifications
| Configuration | Technical parameters | IMPA correspondence |
|---|---|---|
| APP 11/1200 · 180B3212 |
| A direct IMPA code is not confirmed |
| APP 11/1500 · 180B3211 |
| A direct IMPA code is not confirmed |
Selection and applicability
APP, APP W, APP S and ATEX articles are not interchangeable by name. Only the explicitly selected standard APP/APP W articles are shown. All barg values are gauge pressures. The 2024 dry mass is not the net/gross mass of a current article page; confirm revision and shipping mass before ordering. Tables state ambient 0–50 °C, section 8.1 states 2–50 °C; agree operation at 0–2 °C. Check fluid temperature and corrosion resistance against NaCl concentration. No exact IMPA code is confirmed for these additions.
Photographs and drawings


Include with your enquiry
- Fluid, temperature, viscosity and solids
- Flow and pressure at the duty point; operating cycle
- Materials, seals, threads and available power or compressed air
Related sections
Request an offer
The specification, documents and supply terms are agreed for your enquiry. Supplier stock, lead time and price are confirmed in a separate offer.