Axial-piston pump for reverse-osmosis systems. Parameters use the checked Danfoss 2024.06 data-sheet revision. Tabulated flow belongs to the stated speed and maximum table pressure, not any arbitrary duty point. Sound is measured on a motor-pump unit at maximum pressure and speed, at 1 m under EN ISO20361/EN ISO3744; it is not a noise guarantee for every installation. Pump, drive, coupling, filtration and supply scope are agreed separately.

Technical parameters

Technical source revision
AI274333290009en-000702 · 2024.06
Table fluid temperature
2–50 °C; depends on NaCl
Table ambient temperature
0–50 °C; see source qualification
Inlet filtration, section 9.1
10 µm absolute; efficiency 99.98%; β10 ≥5000
Integrated flushing valve
Not available on APP(W)5.1–10.2
Inlet/outlet on sheet 29
M42 × 1.5; depth 13 mm
Bleed screw
M6; hex key 5 mm
DIN 6885 parallel key
10 × 8 × 45 mm
Mounting flange on sheet 29
ISO 3019-2 125AHW
Dimension line 276 on sheet 29
276 mm

Configurations and specifications

ConfigurationTechnical parametersIMPA correspondence
APP 8.2 · 180B3008
  • Manufacturer article: 180B3008
  • Geometric displacement: 80.4 cm³/rev
  • Minimum/maximum outlet pressure: 20 / 83 barg
  • Continuous inlet pressure: 0.5–5 barg
  • Peak inlet pressure: 5 barg
  • Continuous speed: 700–1800 rpm
  • Typical flow at 1000 rpm and maximum pressure: 4.62 m³/h
  • Typical flow at 1500 rpm and maximum pressure: 6.93 m³/h
  • Torque at maximum outlet pressure: 112 Nm
  • Dry weight in 2024 data sheet: 30 kg
  • Table motor-pump sound pressure, 1 m: 78 dB(A)
  • Footprint with recommended IEC motor, excluding service: 0.35 m²
  • Typical drive at maximum speed/pressure, not package scope: 22 kW
  • Typical flow at 1200 rpm and maximum pressure, source unit: 24.39 gpm
  • Typical flow at 1800 rpm and maximum pressure, source unit: 36.59 gpm
  • Typical drive at additional tabulated duty, not package scope: 20 HP at 1200 rpm
  • Inlet boost above 1500 rpm: 2–5 barg
  • Execution duty: Seawater or brackish-water RO
A direct IMPA code is not confirmed
APP W 8.2 · 180B3078
  • Manufacturer article: 180B3078
  • Geometric displacement: 80.4 cm³/rev
  • Minimum/maximum outlet pressure: 20 / 83 barg
  • Continuous inlet pressure: 0.5–5 barg
  • Peak inlet pressure: 5 barg
  • Continuous speed: 700–1800 rpm
  • Typical flow at 1000 rpm and maximum pressure: 4.62 m³/h
  • Typical flow at 1500 rpm and maximum pressure: 6.93 m³/h
  • Torque at maximum outlet pressure: 112 Nm
  • Dry weight in 2024 data sheet: 30 kg
  • Table motor-pump sound pressure, 1 m: 78 dB(A)
  • Footprint with recommended IEC motor, excluding service: 0.35 m²
  • Typical drive at maximum speed/pressure, not package scope: 22 kW
  • Typical flow at 1200 rpm and maximum pressure, source unit: 24.39 gpm
  • Typical flow at 1800 rpm and maximum pressure, source unit: 36.59 gpm
  • Typical drive at additional tabulated duty, not package scope: 20 HP at 1200 rpm
  • Inlet boost above 1500 rpm: 2–5 barg
  • Execution duty: Conditioned wastewater; confirm fluid quality
A direct IMPA code is not confirmed

Selection and applicability

APP, APP W, APP S and ATEX articles are not interchangeable by name. Only the explicitly selected standard APP/APP W articles are shown. All barg values are gauge pressures. The 2024 dry mass is not the net/gross mass of a current article page; confirm revision and shipping mass before ordering. Tables state ambient 0–50 °C, section 8.1 states 2–50 °C; agree operation at 0–2 °C. Check fluid temperature and corrosion resistance against NaCl concentration. No exact IMPA code is confirmed for these additions.

Photographs and drawings

Include with your enquiry

  • Fluid, temperature, viscosity and solids
  • Flow and pressure at the duty point; operating cycle
  • Materials, seals, threads and available power or compressed air

Request an offer

The specification, documents and supply terms are agreed for your enquiry. Supplier stock, lead time and price are confirmed in a separate offer.