Lubrication-pump configurations documented in SKF brochure 1-1202-EN, September 2010. Selection uses the exact designation, lubricant, system cycle and supply. Confirm the current specification, availability and package before order.

Technical parameters

Parameter source
SKF 1-1202-EN / September 2010, page 7
Lubricant
Oil
Tabulated flow reference conditions
140 mm²/s; 5 bar back pressure (catalogue footnote 2)

Configurations and specifications

ConfigurationTechnical parametersIMPA correspondence
MFE5-2000
  • Catalogue designation; power code to confirm: MFE5-2000
  • Tabulated flow: 0.5 l/min
  • Tabulated maximum back pressure: 28 bar
  • 2010 row features: Basic version, NBR, plastic terminal box
A direct IMPA code is not confirmed
MFE5-3041
  • Catalogue designation; power code to confirm: MFE5-3041
  • Tabulated flow: 0.5 l/min
  • Tabulated maximum back pressure: 28 bar
  • 2010 row features: Basic version, NBR, metal terminal box
A direct IMPA code is not confirmed
MFE5-2000-D
  • Catalogue designation; power code to confirm: MFE5-2000-D
  • Tabulated flow: 0.5 l/min
  • Tabulated maximum back pressure: 28 bar
  • 2010 row features: Installed below oil level, NBR, plastic terminal box
A direct IMPA code is not confirmed
MFE5-3000-D
  • Catalogue designation; power code to confirm: MFE5-3000-D
  • Tabulated flow: 0.5 l/min
  • Tabulated maximum back pressure: 28 bar
  • 2010 row features: Installed below oil level, NBR, metal terminal box
A direct IMPA code is not confirmed
MFE5-2008
  • Catalogue designation; power code to confirm: MFE5-2008
  • Tabulated flow: 0.5 l/min
  • Tabulated maximum back pressure: 28 bar
  • 2010 row features: Basic version, FKM (FPM), plastic terminal box
A direct IMPA code is not confirmed
MFE5-2009
  • Catalogue designation; power code to confirm: MFE5-2009
  • Tabulated flow: 0.25 l/min
  • Tabulated maximum back pressure: 17.5 bar
  • 2010 row features: For low-viscosity oil at 5 mm²/s, NBR
A direct IMPA code is not confirmed
MFE5-2053
  • Catalogue designation; power code to confirm: MFE5-2053
  • Tabulated flow: 0.25 l/min
  • Tabulated maximum back pressure: 17.5 bar
  • 2010 row features: For low-viscosity oil at 5 mm²/s, FKM
A direct IMPA code is not confirmed
MFE5-4000
  • Catalogue designation; power code to confirm: MFE5-4000
  • Tabulated flow: 0.5 l/min
  • Tabulated maximum back pressure: 28 bar
  • 2010 row features: NBR, UL/CSA marking in the 2010 catalogue; documents to be confirmed
A direct IMPA code is not confirmed
MFE5-5000
  • Catalogue designation; power code to confirm: MFE5-5000
  • Tabulated flow: 0.5 l/min
  • Tabulated maximum back pressure: 28 bar
  • 2010 row features: NBR, CCC marking in the 2010 catalogue; documents to be confirmed
A direct IMPA code is not confirmed
MFE5-1001
  • Catalogue designation; power code to confirm: MFE5-1001
  • Tabulated flow: 0.5 l/min
  • Tabulated maximum back pressure: 28 bar
  • 2010 row features: Harting HAN6ES, NBR, motor turned 180°
A direct IMPA code is not confirmed
MFE5-1088
  • Catalogue designation; power code to confirm: MFE5-1088
  • Tabulated flow: 0.5 l/min
  • Tabulated maximum back pressure: 28 bar
  • 2010 row features: Harting HAN10ES, FKM
A direct IMPA code is not confirmed
MFE5-S67
  • Catalogue designation; power code to confirm: MFE5-S67
  • Tabulated flow: 0.5 l/min
  • Tabulated maximum back pressure: 28 bar
  • 2010 row features: 50/95 weatherproofing, NBR, metal terminal box
A direct IMPA code is not confirmed

Selection and applicability

Archived 09/2010 edition available from the official SKF CDN and checked 6 Nov 2026; it does not guarantee unchanged design or current production of every option. The MFE series also appears in official SKF 17046EN Product catalogue 2025, but values from different publications are not merged here. Agree the full power code separately; suffix combinations are not generated. Level-switch ratings do not establish whole-unit protection or temperature. No exact IMPA code is confirmed. This is the MFE5 unit for reservoir flange mounting, not ME5 with a separate reservoir. The table warns that variant geometry can differ, so the generic MFE5 figure is not assigned as an exact drawing to all 12 configurations. Shown-motor ratings on page 7 are not automatically assigned to every version. For single-phase supply the source permits only 60% of the tabulated back pressure and requires the appropriate limiting valve; 28 bar must not automatically be applied to a single-phase configuration.

Include with your enquiry

  • Fluid, temperature, viscosity and solids
  • Flow and pressure at the duty point; operating cycle
  • Materials, seals, threads and available power or compressed air

Request an offer

The specification, documents and supply terms are agreed for your enquiry. Supplier stock, lead time and price are confirmed in a separate offer.