Skip to content
  1. Home
  2. Equipment catalogue
  3. Industrial and air-operated pumps
  4. VOITH IPV5-64 hydraulic pump

ХАЛЛ ГРУПП · Equipment catalogue

VOITH IPV5-64 hydraulic pump

Internal gear pumps for constant-speed drives using HLP mineral hydraulic oils. Tabulated flow and pressures apply at 20–40 mm²/s viscosity and 0.8–3 bar absolute inlet pressure. Peak pressures apply for 15% of operating time with a cycle not exceeding 1 minute. Price, lead time and supplier stock are confirmed per enquiry. Production tolerances can reduce displacement by up to 1.5%; peak pressures at other speeds require manufacturer confirmation.

Technical parameters

Design
Internal gears, radial and axial sealing gap compensation
Pressure fluid
HLP mineral oils; DIN 51524 part 2 or 3
Line mounting
SAE J518C Code 61
Viscosity range
10–300 mm²/s
Fluid temperature
−20…+80 °C

Configurations and specifications

ConfigurationTechnical parametersIMPA correspondence
IPV5-64
  • Displacement: 64.9 cm³/rev
  • Tabulated delivery at 1500 rpm: 97.3 L/min
  • Speed range: 400–2200 rpm
  • Continuous pressure: 230 bar
  • Peak pressure at 1500 rpm: 250 bar
  • Peak pressure at maximum speed: 250 bar
  • Moment of inertia: 14.40 kg·cm²
  • Dimension c in drawing 0/1: 143 mm
  • Dimension e in drawing 0/1: 36 mm
  • Dimension g in drawing 0/1: 23 mm
  • Dimension h in drawing 0/1: 40 mm
  • Dimension i in drawing 0/1: 69.9 mm
  • Dimension k in drawing 0/1: 35.7 mm
  • Dimension l in drawing 0/1: M12 x 20
  • Dimension r in drawing 0/1: 52.4 mm
  • Dimension v in drawing 0/1: 26.2 mm
  • Dimension w in drawing 0/1: M10 x 15
  • Mass: flange 0 / shaft end 1: 19.1 kg
  • SAE flange numbers: pair as printed: 12 / 30
A direct IMPA code is not confirmed

Selection and applicability

Selection requires full designation, rotation, mounting flange, shaft end and ports. Dimensions and mass apply only to configuration 0/1; c is not overall length. Stage combinations and multi-flow assembly interchangeability need separate confirmation. No exact IMPA code is verified. For oil-immersed installation, flange 0 must not be used; the manufacturer specifies flange 7.

Photographs and drawings

Include with your enquiry

  • Fluid, temperature, viscosity and solids
  • Flow and pressure at the duty point; operating cycle
  • Materials, seals, threads and available power or compressed air

Request an offer

The specification, documents and supply terms are agreed for your enquiry. Supplier stock, lead time and price are confirmed in a separate offer.