Internal gear pumps for constant-speed drives using HLP mineral hydraulic oils. Tabulated flow and pressures apply at 20–40 mm²/s viscosity and 0.8–3 bar absolute inlet pressure. Peak pressures apply for 15% of operating time with a cycle not exceeding 1 minute. Price, lead time and supplier stock are confirmed per enquiry. Production tolerances can reduce displacement by up to 1.5%; peak pressures at other speeds require manufacturer confirmation.

Technical parameters

Design
Internal gears, radial and axial sealing gap compensation
Pressure fluid
HLP mineral oils; DIN 51524 part 2 or 3
Line mounting
SAE J518C Code 61
Viscosity range
10–300 mm²/s
Fluid temperature
−20…+80 °C

Configurations and specifications

ConfigurationTechnical parametersIMPA correspondence
IPV7-125
  • Displacement: 125.8 cm³/rev
  • Tabulated delivery at 1500 rpm: 188.7 L/min
  • Speed range: 400–2200 rpm
  • Continuous pressure: 300 bar
  • Peak pressure at 1500 rpm: 330 bar
  • Peak pressure at maximum speed: 300 bar
  • Moment of inertia: 84.05 kg·cm²
  • Dimension c in drawing 1/1: 152 mm
  • Dimension e in drawing 1/1: 48 mm
  • Dimension g in drawing 1/1: 30 mm
  • Dimension h in drawing 1/1: 50 mm
  • Dimension i in drawing 1/1: 77.8 mm
  • Dimension k in drawing 1/1: 42.9 mm
  • Dimension l in drawing 1/1: M12 x 20
  • Dimension r in drawing 1/1: 69.9 mm
  • Dimension v in drawing 1/1: 35.7 mm
  • Dimension w in drawing 1/1: M12 x 20
  • Mass: flange 1 / shaft end 1: 46.5 kg
  • SAE flange numbers: pair as printed: 14 / 15
A direct IMPA code is not confirmed
IPV7-160
  • Displacement: 160.8 cm³/rev
  • Tabulated delivery at 1500 rpm: 241.2 L/min
  • Speed range: 400–2000 rpm
  • Continuous pressure: 280 bar
  • Peak pressure at 1500 rpm: 315 bar
  • Peak pressure at maximum speed: 280 bar
  • Moment of inertia: 102.60 kg·cm²
  • Dimension c in drawing 1/1: 162 mm
  • Dimension e in drawing 1/1: 48 mm
  • Dimension g in drawing 1/1: 30 mm
  • Dimension h in drawing 1/1: 56 mm
  • Dimension i in drawing 1/1: 88.9 mm
  • Dimension k in drawing 1/1: 50.8 mm
  • Dimension l in drawing 1/1: M12 x 20
  • Dimension r in drawing 1/1: 69.9 mm
  • Dimension v in drawing 1/1: 35.7 mm
  • Dimension w in drawing 1/1: M12 x 20
  • Mass: flange 1 / shaft end 1: 50.0 kg
  • SAE flange numbers: pair as printed: 14 / 16
A direct IMPA code is not confirmed
IPV7-200
  • Displacement: 202.7 cm³/rev
  • Tabulated delivery at 1500 rpm: 304.0 L/min
  • Speed range: 400–1800 rpm
  • Continuous pressure: 250 bar
  • Peak pressure at 1500 rpm: 300 bar
  • Peak pressure at maximum speed: 270 bar
  • Moment of inertia: 119.00 kg·cm²
  • Dimension c in drawing 1/1: 174 mm
  • Dimension e in drawing 1/1: 46 mm
  • Dimension g in drawing 1/1: 34 mm
  • Dimension h in drawing 1/1: 62 mm
  • Dimension i in drawing 1/1: 88.9 mm
  • Dimension k in drawing 1/1: 50.8 mm
  • Dimension l in drawing 1/1: M12 x 20
  • Dimension r in drawing 1/1: 69.9 mm
  • Dimension v in drawing 1/1: 35.7 mm
  • Dimension w in drawing 1/1: M12 x 20
  • Mass: flange 1 / shaft end 1: 54.0 kg
  • SAE flange numbers: pair as printed: 14 / 16
A direct IMPA code is not confirmed
IPV7-250
  • Displacement: 251.7 cm³/rev
  • Tabulated delivery at 1500 rpm: 377.5 L/min
  • Speed range: 400–1800 rpm
  • Continuous pressure: 210 bar
  • Peak pressure at 1500 rpm: 250 bar
  • Peak pressure at maximum speed: 250 bar
  • Moment of inertia: 144.50 kg·cm²
  • Dimension c in drawing 1/1: 188 mm
  • Dimension e in drawing 1/1: 42 mm
  • Dimension g in drawing 1/1: 38 mm
  • Dimension h in drawing 1/1: 72 mm
  • Dimension i in drawing 1/1: 106.3 mm
  • Dimension k in drawing 1/1: 61.9 mm
  • Dimension l in drawing 1/1: M16 x 25
  • Dimension r in drawing 1/1: 69.9 mm
  • Dimension v in drawing 1/1: 35.7 mm
  • Dimension w in drawing 1/1: M12 x 20
  • Mass: flange 1 / shaft end 1: 59.0 kg
  • SAE flange numbers: pair as printed: 14 / 17
A direct IMPA code is not confirmed

Selection and applicability

Selection requires full designation, rotation, mounting flange, shaft end and ports. Dimensions and mass apply only to configuration 1/1; c is not overall length. Stage combinations and multi-flow assembly interchangeability need separate confirmation. No exact IMPA code is verified.

Photographs and drawings

Include with your enquiry

  • Fluid, temperature, viscosity and solids
  • Flow and pressure at the duty point; operating cycle
  • Materials, seals, threads and available power or compressed air

Request an offer

The specification, documents and supply terms are agreed for your enquiry. Supplier stock, lead time and price are confirmed in a separate offer.