UNITOR HPC STATIONARY 6P stationary pressure washer
Stationary cold-water unit UNITOR HPC STATIONARY 6P for up to 6 simultaneous operators. The selected table specifies440V,60Hz,3phases; alternative supply and accessories are agreed separately.
Technical parameters
- Wilhelmsen / UNITOR article
- 729406
- Invent Hazard Material (IMO/EU) classification
- D-1
- Height x Length x Width [mm]
- 1800 x 970 x 1050
- Weight [kg]
- 526
- Amperage [A]
- 87
- Electrical phase
- 3
- Frequency [Hz]
- 60
- Ingress protection
- X5
- Inlet water temperature [°C]
- 70 maximum
- Operating pressure [bar]
- 200
- Power rating [kW]
- 53
- Voltage [V]
- 440 mains supply
- Water flow rate [l/min]
- 128.3 maximum
Configurations and specifications
| Configuration | Technical parameters | IMPA correspondence |
|---|---|---|
| Article 729406 |
| A direct IMPA code is not confirmed |
Selection and applicability
Parameters retain manufacturer article 729406, printed page276. Dimensions preserve Height×Length×Width. Maximum pressure and flow are not stated as one duty point. Operating pressure is not replaced by a maximum value;440V/60Hz is not equated to400V/50Hz. The source protection labelX5 is retained literally, not expanded toIPX5. No printed catalogue edition date is established; the source filename is not an edition date. No exact IMPA code is confirmed. The gallery includes installation clearances and connections from manualVersionb107309174; confirm applicability to the offered unit. Checked17.11.2026: the manufacturer page states135L/min and water up to85°C; the source PDF states128.3L/min and70°C. This card retains the PDF parameters; confirm revision and execution before ordering.
Photographs and drawings



Related UNITOR catalogue
Include with your enquiry
- Surface material, contamination and required cleaning result
- Working pressure, flow and number of guns used simultaneously
- Drive type and supply requirements: electric power for electric units, compressed air, hydraulics or engine; hoses, nozzles and safety requirements
Related sections
Request an offer
The specification, documents and supply terms are agreed for your enquiry. Supplier stock, lead time and price are confirmed in a separate offer.