| APP 16/1200 · 180B3254 | - Danfoss ordering code: 180B3254
- Source model column: APP 16/1200
- Manufacturer execution: APP
- Geometric displacement [cm³/rev.]: 234.6 cm³/rev.
- Geometric displacement [in³/rev.]: 14.32 in³/rev.
- Maximum continuous outlet pressure [barg]: 83 barg
- Maximum continuous outlet pressure [psig]: 1200 psig
- Minimum outlet pressure [barg]: 10 barg
- Minimum outlet pressure [psig]: 145 psig
- Continuous inlet pressure [barg]: 2 - 5 barg
- Continuous inlet pressure [psig]: 29 - 72.5 psig
- Peak inlet pressure [barg]: 10 barg
- Peak inlet pressure [psig]: 145 psig
- Minimum continuous speed [rpm]: 700 rpm
- Tabulated maximum continuous speed [rpm]: 1200 rpm
- Typical flow at 1000 rpm and maximum pressure [m³/h]: 13.38 m³/h
- Typical flow at 1200 rpm and maximum pressure [gpm]: 70.70 gpm
- Fluid temperature; subject to NaCl concentration [°C]: 2 - 50 °C
- Fluid temperature; subject to NaCl concentration [°F]: 35.6 - 122 °F
- Table ambient temperature; see qualification [°C]: 0 - 50 °C
- Table ambient temperature; see qualification [°F]: 32 - 122 °F
- Dry pump weight [kg]: 78 kg
- Dry pump weight [lb]: 172 lb
- Sound pressure under footnote 4 conditions [dB(A)]: 84 dB(A)
- Footprint with reference IEC motor, footnote 5 [m²]: 0.54 m²
- Footprint with reference IEC motor, footnote 5 [foot²]: 5.81 foot²
- Typical motor power at 1200 rpm and maximum pressure [HP]: 60.0 HP
- Torque at maximum outlet pressure [Nm]: 316 Nm
- Torque at maximum outlet pressure [lbf-ft]: 233 lbf-ft
- Axial body reference callout; not the complete unit envelope: 347.4 mm
- Body diameter in dimensioned view: Ø222 mm
- Pump inlet per dimensioned view: M52x1.5; depth 21 mm
- Pump outlet per dimensioned view: M52x1.5; depth 21 mm
- DIN6885 parallel key: 12 x 8 x 70 mm
- Bleed port: G1/4; hex key6mm
- Earth connection / depth: M8 / 8 mm
- Thermal sensor / depth: M6 / 8 mm
| A direct IMPA code is not confirmed |
|---|
| APP 16/1200 Ex · 180B3264 | - Danfoss ordering code: 180B3264
- Source model column: APP 16/1200
- Manufacturer execution: ATEX
- Geometric displacement [cm³/rev.]: 234.6 cm³/rev.
- Geometric displacement [in³/rev.]: 14.32 in³/rev.
- Maximum continuous outlet pressure [barg]: 83 barg
- Maximum continuous outlet pressure [psig]: 1200 psig
- Minimum outlet pressure [barg]: 10 barg
- Minimum outlet pressure [psig]: 145 psig
- Continuous inlet pressure [barg]: 2 - 5 barg
- Continuous inlet pressure [psig]: 29 - 72.5 psig
- Peak inlet pressure [barg]: 10 barg
- Peak inlet pressure [psig]: 145 psig
- Minimum continuous speed [rpm]: 700 rpm
- Tabulated maximum continuous speed [rpm]: 1200 rpm
- Typical flow at 1000 rpm and maximum pressure [m³/h]: 13.38 m³/h
- Typical flow at 1200 rpm and maximum pressure [gpm]: 70.70 gpm
- Fluid temperature; subject to NaCl concentration [°C]: 2 - 50 °C
- Fluid temperature; subject to NaCl concentration [°F]: 35.6 - 122 °F
- Table ambient temperature; see qualification [°C]: 0 - 50 °C
- Table ambient temperature; see qualification [°F]: 32 - 122 °F
- Dry pump weight [kg]: 78 kg
- Dry pump weight [lb]: 172 lb
- Sound pressure under footnote 4 conditions [dB(A)]: 84 dB(A)
- Footprint with reference IEC motor, footnote 5 [m²]: 0.54 m²
- Footprint with reference IEC motor, footnote 5 [foot²]: 5.81 foot²
- Typical motor power at 1200 rpm and maximum pressure [HP]: 60.0 HP
- Torque at maximum outlet pressure [Nm]: 316 Nm
- Torque at maximum outlet pressure [lbf-ft]: 233 lbf-ft
- Axial body reference callout; not the complete unit envelope: 347.4 mm
- Body diameter in dimensioned view: Ø222 mm
- Pump inlet per dimensioned view: M52x1.5; depth 21 mm
- Pump outlet per dimensioned view: M52x1.5; depth 21 mm
- DIN6885 parallel key: 12 x 8 x 70 mm
- Bleed port: G1/4; hex key6mm
- Earth connection / depth: M8 / 8 mm
- Thermal sensor / depth: M6 / 8 mm
- ATEX catalogue-data status: Manufacturer ATEX catalogue execution; confirm certificate, category and zone separately
| A direct IMPA code is not confirmed |
|---|
| APP 16/1500 · 180B3250 | - Danfoss ordering code: 180B3250
- Source model column: APP 16/1500
- Manufacturer execution: APP
- Geometric displacement [cm³/rev.]: 188.3 cm³/rev.
- Geometric displacement [in³/rev.]: 11.49 in³/rev.
- Maximum continuous outlet pressure [barg]: 70 barg
- Maximum continuous outlet pressure [psig]: 1015 psig
- Minimum outlet pressure [barg]: 10 barg
- Minimum outlet pressure [psig]: 145 psig
- Continuous inlet pressure [barg]: 2 - 5 barg
- Continuous inlet pressure [psig]: 29 - 72.5 psig
- Peak inlet pressure [barg]: 10 barg
- Peak inlet pressure [psig]: 145 psig
- Minimum continuous speed [rpm]: 700 rpm
- Tabulated maximum continuous speed [rpm]: 1500 rpm
- Typical flow at 1000 rpm and maximum pressure [m³/h]: 10.67 m³/h
- Typical flow at 1500 rpm and maximum pressure [m³/h]: 16.01 m³/h
- Typical flow at 1200 rpm and maximum pressure [gpm]: 56.40 gpm
- Fluid temperature; subject to NaCl concentration [°C]: 2 - 50 °C
- Fluid temperature; subject to NaCl concentration [°F]: 35.6 - 122 °F
- Table ambient temperature; see qualification [°C]: 0 - 50 °C
- Table ambient temperature; see qualification [°F]: 32 - 122 °F
- Dry pump weight [kg]: 78 kg
- Dry pump weight [lb]: 172 lb
- Sound pressure under footnote 4 conditions [dB(A)]: 84 dB(A)
- Footprint with reference IEC motor, footnote 5 [m²]: 0.58 m²
- Footprint with reference IEC motor, footnote 5 [foot²]: 6.26 foot²
- Typical motor power at maximum speed and pressure [kW]: 37.0 kW
- Torque at maximum outlet pressure [Nm]: 223 Nm
- Torque at maximum outlet pressure [lbf-ft]: 165 lbf-ft
- Axial body reference callout; not the complete unit envelope: 347.4 mm
- Body diameter in dimensioned view: Ø222 mm
- Pump inlet per dimensioned view: M52x1.5; depth 21 mm
- Pump outlet per dimensioned view: M52x1.5; depth 21 mm
- DIN6885 parallel key: 12 x 8 x 70 mm
- Bleed port: G1/4; hex key6mm
- Earth connection / depth: M8 / 8 mm
- Thermal sensor / depth: M6 / 8 mm
| A direct IMPA code is not confirmed |
|---|
| APP 16/1500 Ex · 180B3260 | - Danfoss ordering code: 180B3260
- Source model column: APP 16/1500
- Manufacturer execution: ATEX
- Geometric displacement [cm³/rev.]: 188.3 cm³/rev.
- Geometric displacement [in³/rev.]: 11.49 in³/rev.
- Maximum continuous outlet pressure [barg]: 70 barg
- Maximum continuous outlet pressure [psig]: 1015 psig
- Minimum outlet pressure [barg]: 10 barg
- Minimum outlet pressure [psig]: 145 psig
- Continuous inlet pressure [barg]: 2 - 5 barg
- Continuous inlet pressure [psig]: 29 - 72.5 psig
- Peak inlet pressure [barg]: 10 barg
- Peak inlet pressure [psig]: 145 psig
- Minimum continuous speed [rpm]: 700 rpm
- Tabulated maximum continuous speed [rpm]: 1500 rpm
- Typical flow at 1000 rpm and maximum pressure [m³/h]: 10.67 m³/h
- Typical flow at 1500 rpm and maximum pressure [m³/h]: 16.01 m³/h
- Typical flow at 1200 rpm and maximum pressure [gpm]: 56.40 gpm
- Fluid temperature; subject to NaCl concentration [°C]: 2 - 50 °C
- Fluid temperature; subject to NaCl concentration [°F]: 35.6 - 122 °F
- Table ambient temperature; see qualification [°C]: 0 - 50 °C
- Table ambient temperature; see qualification [°F]: 32 - 122 °F
- Dry pump weight [kg]: 78 kg
- Dry pump weight [lb]: 172 lb
- Sound pressure under footnote 4 conditions [dB(A)]: 84 dB(A)
- Footprint with reference IEC motor, footnote 5 [m²]: 0.58 m²
- Footprint with reference IEC motor, footnote 5 [foot²]: 6.26 foot²
- Typical motor power at maximum speed and pressure [kW]: 37.0 kW
- Torque at maximum outlet pressure [Nm]: 223 Nm
- Torque at maximum outlet pressure [lbf-ft]: 165 lbf-ft
- Axial body reference callout; not the complete unit envelope: 347.4 mm
- Body diameter in dimensioned view: Ø222 mm
- Pump inlet per dimensioned view: M52x1.5; depth 21 mm
- Pump outlet per dimensioned view: M52x1.5; depth 21 mm
- DIN6885 parallel key: 12 x 8 x 70 mm
- Bleed port: G1/4; hex key6mm
- Earth connection / depth: M8 / 8 mm
- Thermal sensor / depth: M6 / 8 mm
- ATEX catalogue-data status: Manufacturer ATEX catalogue execution; confirm certificate, category and zone separately
| A direct IMPA code is not confirmed |
|---|