| APP 30/1200 · 180B3060 | - Danfoss ordering code: 180B3060
- Source model column: APP 30/1200
- Manufacturer execution: APP
- Geometric displacement [cm³/rev.]: 444 cm³/rev.
- Geometric displacement [in³/rev.]: 27.09 in³/rev.
- Maximum continuous outlet pressure [barg]: 83 barg
- Maximum continuous outlet pressure [psig]: 1200 psig
- Minimum outlet pressure [barg]: 10 barg
- Minimum outlet pressure [psig]: 145 psig
- Continuous inlet pressure [barg]: 2 - 5 barg
- Continuous inlet pressure [psig]: 29 - 72.5 psig
- Peak inlet pressure [barg]: 10 barg
- Peak inlet pressure [psig]: 145 psig
- Minimum continuous speed [rpm]: 700 rpm
- Tabulated maximum continuous speed [rpm]: 1200 rpm
- Typical flow at 1000 rpm and maximum pressure [m³/h]: 26.05 m³/h
- Typical flow at 1200 rpm and maximum pressure [gpm]: 137.64 gpm
- Fluid temperature; subject to NaCl concentration [°C]: 2 - 50 °C
- Fluid temperature; subject to NaCl concentration [°F]: 35.6 - 122 °F
- Table ambient temperature; see qualification [°C]: 0 - 50 °C
- Table ambient temperature; see qualification [°F]: 32 - 122 °F
- Dry pump weight [kg]: 105 kg
- Dry pump weight [lb]: 231 lb
- Sound pressure under footnote 4 conditions [dB(A)]: 85 dB(A)
- Footprint with reference IEC motor, footnote 5 [m²]: 0.83 m²
- Footprint with reference IEC motor, footnote 5 [foot²]: 8.93 foot²
- Typical motor power at maximum speed and pressure [kW]: 90.0 kW
- Typical motor power at 1200 rpm and maximum pressure [HP]: 125.0 HP
- Torque at maximum outlet pressure [Nm]: 608 Nm
- Torque at maximum outlet pressure [lbf-ft]: 449 lbf-ft
- Axial body reference callout; not the complete unit envelope: 357.4 mm
- Body diameter in dimensioned view: Ø279 mm
- Pump inlet per dimensioned view: M60x1.5; depth 23 mm
- Pump outlet per dimensioned view: M60x1.5; depth 23 mm
- DIN6885 parallel key: 12 x 8 x 70 mm
- Bleed port: G1/4; hex key6mm
- Earth connection / depth: M8 / 11 mm
- Thermal sensor / depth: M6 / 11 mm
| A direct IMPA code is not confirmed |
|---|
| APP S 30/1200 · 180B3276 | - Danfoss ordering code: 180B3276
- Source model column: APP 30/1200
- Manufacturer execution: APP S
- Geometric displacement [cm³/rev.]: 444 cm³/rev.
- Geometric displacement [in³/rev.]: 27.09 in³/rev.
- Maximum continuous outlet pressure [barg]: 83 barg
- Maximum continuous outlet pressure [psig]: 1200 psig
- Minimum outlet pressure [barg]: 10 barg
- Minimum outlet pressure [psig]: 145 psig
- Continuous inlet pressure [barg]: 2 - 5 barg
- Continuous inlet pressure [psig]: 29 - 72.5 psig
- Peak inlet pressure [barg]: 10 barg
- Peak inlet pressure [psig]: 145 psig
- Minimum continuous speed [rpm]: 700 rpm
- Tabulated maximum continuous speed [rpm]: 1200 rpm
- Typical flow at 1000 rpm and maximum pressure [m³/h]: 26.05 m³/h
- Typical flow at 1200 rpm and maximum pressure [gpm]: 137.64 gpm
- Fluid temperature; subject to NaCl concentration [°C]: 2 - 50 °C
- Fluid temperature; subject to NaCl concentration [°F]: 35.6 - 122 °F
- Table ambient temperature; see qualification [°C]: 0 - 50 °C
- Table ambient temperature; see qualification [°F]: 32 - 122 °F
- Dry pump weight [kg]: 105 kg
- Dry pump weight [lb]: 231 lb
- Sound pressure under footnote 4 conditions [dB(A)]: 85 dB(A)
- Footprint with reference IEC motor, footnote 5 [m²]: 0.83 m²
- Footprint with reference IEC motor, footnote 5 [foot²]: 8.93 foot²
- Typical motor power at maximum speed and pressure [kW]: 90.0 kW
- Typical motor power at 1200 rpm and maximum pressure [HP]: 125.0 HP
- Torque at maximum outlet pressure [Nm]: 608 Nm
- Torque at maximum outlet pressure [lbf-ft]: 449 lbf-ft
- Axial body reference callout; not the complete unit envelope: 357.4 mm
- Body diameter in dimensioned view: Ø279 mm
- Pump inlet per dimensioned view: M60x1.5; depth 23 mm
- Pump outlet per dimensioned view: M60x1.5; depth 23 mm
- DIN6885 parallel key: 12 x 8 x 70 mm
- Bleed port: G1/4; hex key6mm
- Earth connection / depth: M8 / 11 mm
- Thermal sensor / depth: M6 / 11 mm
- APP S wetted parts per manufacturer description: All wetted parts are Super Duplex; see source qualification
| A direct IMPA code is not confirmed |
|---|
| APP 30/1500 · 180B3062 | - Danfoss ordering code: 180B3062
- Source model column: APP 30/1500
- Manufacturer execution: APP
- Geometric displacement [cm³/rev.]: 362 cm³/rev.
- Geometric displacement [in³/rev.]: 22.09 in³/rev.
- Maximum continuous outlet pressure [barg]: 83 barg
- Maximum continuous outlet pressure [psig]: 1200 psig
- Minimum outlet pressure [barg]: 10 barg
- Minimum outlet pressure [psig]: 145 psig
- Continuous inlet pressure [barg]: 2 - 5 barg
- Continuous inlet pressure [psig]: 29 - 72.5 psig
- Peak inlet pressure [barg]: 10 barg
- Peak inlet pressure [psig]: 145 psig
- Minimum continuous speed [rpm]: 700 rpm
- Tabulated maximum continuous speed [rpm]: 1500 rpm
- Typical flow at 1000 rpm and maximum pressure [m³/h]: 21.12 m³/h
- Typical flow at 1500 rpm and maximum pressure [m³/h]: 31.69 m³/h
- Typical flow at 1200 rpm and maximum pressure [gpm]: 111.60 gpm
- Fluid temperature; subject to NaCl concentration [°C]: 2 - 50 °C
- Fluid temperature; subject to NaCl concentration [°F]: 35.6 - 122 °F
- Table ambient temperature; see qualification [°C]: 0 - 50 °C
- Table ambient temperature; see qualification [°F]: 32 - 122 °F
- Dry pump weight [kg]: 105 kg
- Dry pump weight [lb]: 231 lb
- Sound pressure under footnote 4 conditions [dB(A)]: 85 dB(A)
- Footprint with reference IEC motor, footnote 5 [m²]: 0.83 m²
- Footprint with reference IEC motor, footnote 5 [foot²]: 8.93 foot²
- Typical motor power at maximum speed and pressure [kW]: 90.0 kW
- Torque at maximum outlet pressure [Nm]: 498.68 Nm
- Torque at maximum outlet pressure [lbf-ft]: 367.81 lbf-ft
- Axial body reference callout; not the complete unit envelope: 351.4 mm
- Body diameter in dimensioned view: Ø279 mm
- Pump inlet per dimensioned view: M60x1.5; depth 23 mm
- Pump outlet per dimensioned view: M60x1.5; depth 23 mm
- DIN6885 parallel key: 12 x 8 x 70 mm
- Bleed port: G1/4; hex key6mm
- Earth connection / depth: M8 / 11 mm
- Thermal sensor / depth: M6 / 11 mm
| A direct IMPA code is not confirmed |
|---|
| APP S 30/1500 · 180B3277 | - Danfoss ordering code: 180B3277
- Source model column: APP 30/1500
- Manufacturer execution: APP S
- Geometric displacement [cm³/rev.]: 362 cm³/rev.
- Geometric displacement [in³/rev.]: 22.09 in³/rev.
- Maximum continuous outlet pressure [barg]: 83 barg
- Maximum continuous outlet pressure [psig]: 1200 psig
- Minimum outlet pressure [barg]: 10 barg
- Minimum outlet pressure [psig]: 145 psig
- Continuous inlet pressure [barg]: 2 - 5 barg
- Continuous inlet pressure [psig]: 29 - 72.5 psig
- Peak inlet pressure [barg]: 10 barg
- Peak inlet pressure [psig]: 145 psig
- Minimum continuous speed [rpm]: 700 rpm
- Tabulated maximum continuous speed [rpm]: 1500 rpm
- Typical flow at 1000 rpm and maximum pressure [m³/h]: 21.12 m³/h
- Typical flow at 1500 rpm and maximum pressure [m³/h]: 31.69 m³/h
- Typical flow at 1200 rpm and maximum pressure [gpm]: 111.60 gpm
- Fluid temperature; subject to NaCl concentration [°C]: 2 - 50 °C
- Fluid temperature; subject to NaCl concentration [°F]: 35.6 - 122 °F
- Table ambient temperature; see qualification [°C]: 0 - 50 °C
- Table ambient temperature; see qualification [°F]: 32 - 122 °F
- Dry pump weight [kg]: 105 kg
- Dry pump weight [lb]: 231 lb
- Sound pressure under footnote 4 conditions [dB(A)]: 85 dB(A)
- Footprint with reference IEC motor, footnote 5 [m²]: 0.83 m²
- Footprint with reference IEC motor, footnote 5 [foot²]: 8.93 foot²
- Typical motor power at maximum speed and pressure [kW]: 90.0 kW
- Torque at maximum outlet pressure [Nm]: 498.68 Nm
- Torque at maximum outlet pressure [lbf-ft]: 367.81 lbf-ft
- Axial body reference callout; not the complete unit envelope: 351.4 mm
- Body diameter in dimensioned view: Ø279 mm
- Pump inlet per dimensioned view: M60x1.5; depth 23 mm
- Pump outlet per dimensioned view: M60x1.5; depth 23 mm
- DIN6885 parallel key: 12 x 8 x 70 mm
- Bleed port: G1/4; hex key6mm
- Earth connection / depth: M8 / 11 mm
- Thermal sensor / depth: M6 / 11 mm
- APP S wetted parts per manufacturer description: All wetted parts are Super Duplex; see source qualification
| A direct IMPA code is not confirmed |
|---|