Skip to content
  1. Home
  2. Equipment catalogue
  3. Industrial, air-operated and drainage pumps
  4. CityPumps SPEED MOP 30M submersible drainage pump

ХАЛЛ ГРУПП · Equipment catalogue

CityPumps SPEED MOP 30M submersible drainage pump

Non-abrasive clear water; domestic and emergency drainage. Complete factory50Hz Q–H row,230/240V currents and the shared30M/50M dimension drawing.

Technical parameters

Pump body
Technopolymer
Impeller
Noryl FE1520PW
Motor shaft
EN10088-3 ·1.4104 stainless steel
Shaft sealing
Double shaft seal with interposed oil chamber; ceramic/graphite/NBR

Configurations and specifications

ConfigurationTechnical parametersIMPA correspondence
SPEED MOP 30M ·50Hz ·single phase
  • Motor output P2: 0.25 kW
  • Catalogue motor output P2: 0.33 HP
  • Curve frequency and speed: 50 Hz ·2900 min⁻¹
  • Current at230V /240V ·single phase: 1.5 A /1.4 A
  • Complete tabulated Q–H points: Q [l/min]: 0, 20, 40, 60, 80, 100, 120; H [m]: 7, 6, 5, 4, 3, 2, 1
  • Outlet: source DN designation: 1¼″
  • Dimensions a /h /h1: 152 /257 /237 mm
  • Dimensional-table mass: 5.0 kg
  • Residual drainage level: 2 mm
  • Depth below water surface: Up to3m with an adequately long supply cable
  • Particles in non-abrasive clear water: max Ø2 mm
  • Temperature and duty: Up to+40°C ·S1; up to+90°C intermittently for at most3min
  • Leaflet cable and plug: H07 RN-F ·5 m ·Schuko
  • Leaflet pallet quantity, not MOQ: 96 pumps
  • Blank table cells: Q140/160l/min: — /—; not extrapolated
A direct IMPA code is not confirmed

Selection and applicability

Values use only the manufacturer speed-mop_it.pdf checked12Nov2026; no printed edition date established. Intended for non-abrasive clear water and domestic/emergency drainage; marine approval and other media are not established. Outlet1¼″ is retained without converting to DN or assigning a thread standard. Select the duty point from the model row; confirm availability and package separately. No exact IMPA verified.

Photographs and drawings

Include with your enquiry

  • Fluid, temperature, viscosity and solids
  • Flow and pressure at the duty point; operating cycle
  • Materials, seals, threads and available power or compressed air

Request an offer

The specification, documents and supply terms are agreed for your enquiry. Supplier stock, lead time and price are confirmed in a separate offer.