Skip to content
  1. Home
  2. Equipment catalogue
  3. Rigging: shackles, clips, ropes and slings
  4. Steel wire ropes 6×19

ХАЛЛ ГРУПП · Equipment catalogue

Steel wire ropes 6×19

Constructions: 6×19+FC; 6×19+IWS; 6×19+IWRC. The table lists diameters, approximate weights and minimum breaking loads by tensile-strength grade.

Photographs and drawings

Technical parameters

Constructions: 6×19+FC; 6×19+IWS; 6×19+IWRC. The table lists diameters, approximate weights and minimum breaking loads by tensile-strength grade.

A diameter row is not a fully specified configuration. Select core and tensile-strength grade from the applicable table columns. Specify construction, core, tensile grade, finish, lay, diameter tolerance and length when ordering. NF denotes natural fibre core, SF synthetic fibre core; FC fibre core and IWRC/IWS steel core follow the table notation. MBL is minimum breaking load, not working load limit. Lifting and special applications require selection calculations and documentation for the supplied configuration.

Scroll the table horizontally. Each diameter row still requires selection of the core and tensile-strength grade.

Steel wire ropes 6×19
ConfigurationDiameter
mm
Weight, natural NF
kg/100m
Weight, synthetic SF
kg/100m
Weight, IWRC/IWS
kg/100m
MBL FC, 1670 MPa
kN
MBL IWRC/IWS, 1670 MPa
kN
MBL FC, 1770 MPa
kN
MBL IWRC/IWS, 1770 MPa
kN
MBL FC, 1870 MPa
kN
MBL IWRC/IWS, 1870 MPa
kN
MBL FC, 1960 MPa
kN
MBL IWRC/IWS, 1960 MPa
kN
MBL FC, 2160 MPa
kN
MBL IWRC/IWS, 2160 MPa
kN
IMPA correspondence
Ø3 mm33.113.033.434.614.994.895.295.175.595.415.855.976.45A direct IMPA code is not confirmed
Ø4 mm45.545.396.108.208.878.699.409.199.939.6210.4010.6111.47212101
Execution requires verification

6×19 · Ø4 mm · 200 m coil

Matching conditions

The base construction 6×19 and nominal diameter 4 mm match; OEM table constructions: 6×19+FC, 6×19+IWS, 6×19+IWRC. IMPA 212101 specifies galvanized steel and a 200 m coil. The OEM row does not establish finish or coil length; galvanized execution and 200 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement.


212126
Execution requires verification

6×19 · Ø4 mm · 220 m coil

Matching conditions

The base construction 6×19 and nominal diameter 4 mm match; OEM table constructions: 6×19+FC, 6×19+IWS, 6×19+IWRC. IMPA 212126 specifies galvanized steel and a 220 m coil. The OEM row does not establish finish or coil length; galvanized execution and 220 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement.

Ø5 mm58.658.439.5312.8013.9013.6014.7014.4015.5015.0016.2016.5817.93212102
Execution requires verification

6×19 · Ø5 mm · 200 m coil

Matching conditions

The base construction 6×19 and nominal diameter 5 mm match; OEM table constructions: 6×19+FC, 6×19+IWS, 6×19+IWRC. IMPA 212102 specifies galvanized steel and a 200 m coil. The OEM row does not establish finish or coil length; galvanized execution and 200 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement.


212127
Execution requires verification

6×19 · Ø5 mm · 220 m coil

Matching conditions

The base construction 6×19 and nominal diameter 5 mm match; OEM table constructions: 6×19+FC, 6×19+IWS, 6×19+IWRC. IMPA 212127 specifies galvanized steel and a 220 m coil. The OEM row does not establish finish or coil length; galvanized execution and 220 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement.

Ø6 mm612.5012.1013.7018.5020.0019.6021.2020.7022.4021.6023.4023.8725.82212103
Execution requires verification

6×19 · Ø6 mm · 200 m coil

Matching conditions

The base construction 6×19 and nominal diameter 6 mm match; OEM table constructions: 6×19+FC, 6×19+IWS, 6×19+IWRC. IMPA 212103 specifies galvanized steel and a 200 m coil. The OEM row does not establish finish or coil length; galvanized execution and 200 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement.


212128
Execution requires verification

6×19 · Ø6 mm · 220 m coil

Matching conditions

The base construction 6×19 and nominal diameter 6 mm match; OEM table constructions: 6×19+FC, 6×19+IWS, 6×19+IWRC. IMPA 212128 specifies galvanized steel and a 220 m coil. The OEM row does not establish finish or coil length; galvanized execution and 220 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement.

Ø7 mm717.0016.5018.7025.1027.2026.6028.8028.1030.4029.4031.8032.4935.14A direct IMPA code is not confirmed
Ø8 mm822.1021.6024.4032.8035.5034.8037.6036.7039.7038.5041.6042.4445.90212105
Execution requires verification

6×19 · Ø8 mm · 200 m coil

Matching conditions

The base construction 6×19 and nominal diameter 8 mm match; OEM table constructions: 6×19+FC, 6×19+IWS, 6×19+IWRC. IMPA 212105 specifies galvanized steel and a 200 m coil. The OEM row does not establish finish or coil length; galvanized execution and 200 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement.


212130
Execution requires verification

6×19 · Ø8 mm · 220 m coil

Matching conditions

The base construction 6×19 and nominal diameter 8 mm match; OEM table constructions: 6×19+FC, 6×19+IWS, 6×19+IWRC. IMPA 212130 specifies galvanized steel and a 220 m coil. The OEM row does not establish finish or coil length; galvanized execution and 220 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement.

Ø9 mm928.0027.3030.9041.5044.9044.0047.6046.5050.3048.7052.7053.7158.09212106
Execution requires verification

6×19 · Ø9 mm · 200 m coil

Matching conditions

The base construction 6×19 and nominal diameter 9 mm match; OEM table constructions: 6×19+FC, 6×19+IWS, 6×19+IWRC. IMPA 212106 specifies galvanized steel and a 200 m coil. The OEM row does not establish finish or coil length; galvanized execution and 200 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement.


212131
Execution requires verification

6×19 · Ø9 mm · 220 m coil

Matching conditions

The base construction 6×19 and nominal diameter 9 mm match; OEM table constructions: 6×19+FC, 6×19+IWS, 6×19+IWRC. IMPA 212131 specifies galvanized steel and a 220 m coil. The OEM row does not establish finish or coil length; galvanized execution and 220 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement.

Ø10 mm1034.6033.7038.1051.3055.4054.3058.8057.4062.1060.0065.0066.3171.71212107
Execution requires verification

6×19 · Ø10 mm · 200 m coil

Matching conditions

The base construction 6×19 and nominal diameter 10 mm match; OEM table constructions: 6×19+FC, 6×19+IWS, 6×19+IWRC. IMPA 212107 specifies galvanized steel and a 200 m coil. The OEM row does not establish finish or coil length; galvanized execution and 200 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement.


212132
Execution requires verification

6×19 · Ø10 mm · 220 m coil

Matching conditions

The base construction 6×19 and nominal diameter 10 mm match; OEM table constructions: 6×19+FC, 6×19+IWS, 6×19+IWRC. IMPA 212132 specifies galvanized steel and a 220 m coil. The OEM row does not establish finish or coil length; galvanized execution and 220 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement.

Ø11 mm1141.9040.8046.1062.0067.1065.8071.1069.5075.1072.8078.7080.2486.77A direct IMPA code is not confirmed
Ø12 mm1249.8048.5054.9073.8079.8078.2084.6082.7089.4086.6093.7095.49103.27212109
Execution requires verification

6×19 · Ø12 mm · 200 m coil

Matching conditions

The base construction 6×19 and nominal diameter 12 mm match; OEM table constructions: 6×19+FC, 6×19+IWS, 6×19+IWRC. IMPA 212109 specifies galvanized steel and a 200 m coil. The OEM row does not establish finish or coil length; galvanized execution and 200 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement.


212134
Execution requires verification

6×19 · Ø12 mm · 220 m coil

Matching conditions

The base construction 6×19 and nominal diameter 12 mm match; OEM table constructions: 6×19+FC, 6×19+IWS, 6×19+IWRC. IMPA 212134 specifies galvanized steel and a 220 m coil. The OEM row does not establish finish or coil length; galvanized execution and 220 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement.

Ø13 mm1358.5057.0064.4086.6093.7091.8099.3097.00105.00101.00110.00112.07121.19A direct IMPA code is not confirmed
Ø14 mm1467.8066.1074.70100.00109.00107.00115.00113.00122.00118.00127.00129.97140.56212111
Execution requires verification

6×19 · Ø14 mm · 200 m coil

Matching conditions

The base construction 6×19 and nominal diameter 14 mm match; OEM table constructions: 6×19+FC, 6×19+IWS, 6×19+IWRC. IMPA 212111 specifies galvanized steel and a 200 m coil. The OEM row does not establish finish or coil length; galvanized execution and 200 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement.


212136
Execution requires verification

6×19 · Ø14 mm · 220 m coil

Matching conditions

The base construction 6×19 and nominal diameter 14 mm match; OEM table constructions: 6×19+FC, 6×19+IWS, 6×19+IWRC. IMPA 212136 specifies galvanized steel and a 220 m coil. The OEM row does not establish finish or coil length; galvanized execution and 220 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement.

Ø16 mm1688.6086.3097.50131.00142.00139.00150.00147.00159.00154.00166.00169.76183.58212112
Execution requires verification

6×19 · Ø16 mm · 200 m coil

Matching conditions

The base construction 6×19 and nominal diameter 16 mm match; OEM table constructions: 6×19+FC, 6×19+IWS, 6×19+IWRC. IMPA 212112 specifies galvanized steel and a 200 m coil. The OEM row does not establish finish or coil length; galvanized execution and 200 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement.


212137
Execution requires verification

6×19 · Ø16 mm · 220 m coil

Matching conditions

The base construction 6×19 and nominal diameter 16 mm match; OEM table constructions: 6×19+FC, 6×19+IWS, 6×19+IWRC. IMPA 212137 specifies galvanized steel and a 220 m coil. The OEM row does not establish finish or coil length; galvanized execution and 220 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement.

Ø18 mm18112.00109.00123.00166.00180.00176.00190.00186.00201.00195.00210.00214.85232.35212113
Execution requires verification

6×19 · Ø18 mm · 200 m coil

Matching conditions

The base construction 6×19 and nominal diameter 18 mm match; OEM table constructions: 6×19+FC, 6×19+IWS, 6×19+IWRC. IMPA 212113 specifies galvanized steel and a 200 m coil. The OEM row does not establish finish or coil length; galvanized execution and 200 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement.


212138
Execution requires verification

6×19 · Ø18 mm · 220 m coil

Matching conditions

The base construction 6×19 and nominal diameter 18 mm match; OEM table constructions: 6×19+FC, 6×19+IWS, 6×19+IWRC. IMPA 212138 specifies galvanized steel and a 220 m coil. The OEM row does not establish finish or coil length; galvanized execution and 220 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement.

Ø20 mm20138.00135.00152.00205.00222.00217.00235.00230.00248.00240.00260.00265.25286.85212114
Execution requires verification

6×19 · Ø20 mm · 200 m coil

Matching conditions

The base construction 6×19 and nominal diameter 20 mm match; OEM table constructions: 6×19+FC, 6×19+IWS, 6×19+IWRC. IMPA 212114 specifies galvanized steel and a 200 m coil. The OEM row does not establish finish or coil length; galvanized execution and 200 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement.


212139
Execution requires verification

6×19 · Ø20 mm · 220 m coil

Matching conditions

The base construction 6×19 and nominal diameter 20 mm match; OEM table constructions: 6×19+FC, 6×19+IWS, 6×19+IWRC. IMPA 212139 specifies galvanized steel and a 220 m coil. The OEM row does not establish finish or coil length; galvanized execution and 220 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement.

Ø22 mm22167.00163.00184.00248.00268.00263.00284.00278.00300.00291.00315.00320.95347.09212115
Execution requires verification

6×19 · Ø22 mm · 200 m coil

Matching conditions

The base construction 6×19 and nominal diameter 22 mm match; OEM table constructions: 6×19+FC, 6×19+IWS, 6×19+IWRC. IMPA 212115 specifies galvanized steel and a 200 m coil. The OEM row does not establish finish or coil length; galvanized execution and 200 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement.


212140
Execution requires verification

6×19 · Ø22 mm · 220 m coil

Matching conditions

The base construction 6×19 and nominal diameter 22 mm match; OEM table constructions: 6×19+FC, 6×19+IWS, 6×19+IWRC. IMPA 212140 specifies galvanized steel and a 220 m coil. The OEM row does not establish finish or coil length; galvanized execution and 220 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement.

Ø24 mm24199.00194.00219.00295.00319.00313.00338.00331.00358.00346.00374.00381.96413.06212117
Execution requires verification

6×19 · Ø24 mm · 200 m coil

Matching conditions

The base construction 6×19 and nominal diameter 24 mm match; OEM table constructions: 6×19+FC, 6×19+IWS, 6×19+IWRC. IMPA 212117 specifies galvanized steel and a 200 m coil. The OEM row does not establish finish or coil length; galvanized execution and 200 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement.


212142
Execution requires verification

6×19 · Ø24 mm · 220 m coil

Matching conditions

The base construction 6×19 and nominal diameter 24 mm match; OEM table constructions: 6×19+FC, 6×19+IWS, 6×19+IWRC. IMPA 212142 specifies galvanized steel and a 220 m coil. The OEM row does not establish finish or coil length; galvanized execution and 220 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement.

Ø26 mm26234.00228.00258.00347.00375.00367.00397.00388.00420.00406.00440.00448.27484.77212119
Execution requires verification

6×19 · Ø26 mm · 200 m coil

Matching conditions

The base construction 6×19 and nominal diameter 26 mm match; OEM table constructions: 6×19+FC, 6×19+IWS, 6×19+IWRC. IMPA 212119 specifies galvanized steel and a 200 m coil. The OEM row does not establish finish or coil length; galvanized execution and 200 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement.


212144
Execution requires verification

6×19 · Ø26 mm · 220 m coil

Matching conditions

The base construction 6×19 and nominal diameter 26 mm match; OEM table constructions: 6×19+FC, 6×19+IWS, 6×19+IWRC. IMPA 212144 specifies galvanized steel and a 220 m coil. The OEM row does not establish finish or coil length; galvanized execution and 220 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement.

Ø28 mm28271.00264.00299.00402.00435.00426.00461.00450.00487.00471.00510.00519.89562.22212120
Execution requires verification

6×19 · Ø28 mm · 200 m coil

Matching conditions

The base construction 6×19 and nominal diameter 28 mm match; OEM table constructions: 6×19+FC, 6×19+IWS, 6×19+IWRC. IMPA 212120 specifies galvanized steel and a 200 m coil. The OEM row does not establish finish or coil length; galvanized execution and 200 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement.


212145
Execution requires verification

6×19 · Ø28 mm · 220 m coil

Matching conditions

The base construction 6×19 and nominal diameter 28 mm match; OEM table constructions: 6×19+FC, 6×19+IWS, 6×19+IWRC. IMPA 212145 specifies galvanized steel and a 220 m coil. The OEM row does not establish finish or coil length; galvanized execution and 220 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement.

Ø30 mm30311.00303.00343.00461.00499.00489.00529.00517.00559.00541.00585.00596.81645.41212121
Execution requires verification

6×19 · Ø30 mm · 200 m coil

Matching conditions

The base construction 6×19 and nominal diameter 30 mm match; OEM table constructions: 6×19+FC, 6×19+IWS, 6×19+IWRC. IMPA 212121 specifies galvanized steel and a 200 m coil. The OEM row does not establish finish or coil length; galvanized execution and 200 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement.


212146
Execution requires verification

6×19 · Ø30 mm · 220 m coil

Matching conditions

The base construction 6×19 and nominal diameter 30 mm match; OEM table constructions: 6×19+FC, 6×19+IWS, 6×19+IWRC. IMPA 212146 specifies galvanized steel and a 220 m coil. The OEM row does not establish finish or coil length; galvanized execution and 220 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement.

Ø32 mm32354.00345.00390.00525.00568.00556.00602.00588.00636.00616.00666.00679.03734.33A direct IMPA code is not confirmed
Ø34 mm34400.00390.00440.00593.00641.00628.00679.00664.00718.00695.00752.00766.57828.99A direct IMPA code is not confirmed
Ø36 mm36448.00437.00494.00664.00719.00704.00762.00744.00805.00780.00843.00859.40929.39A direct IMPA code is not confirmed
Ø38 mm38500.00487.00550.00740.00801.00785.00849.00829.00896.00868.00940.00957.551035.52A direct IMPA code is not confirmed
Ø40 mm40554.00539.00610.00820.00887.00869.00940.00919.00993.00962.001041.001060.991147.39A direct IMPA code is not confirmed
Ø42 mm42610.00594.00672.00904.00978.00959.001040.001010.001100.001061.001147.001169.741265.00A direct IMPA code is not confirmed
Ø44 mm44670.00652.00738.00993.001070.001050.001140.001110.001200.001164.001260.001283.801388.34A direct IMPA code is not confirmed
Ø46 mm46732.00713.00806.001080.001170.001150.001240.001210.001310.001273.001376.001403.161517.43A direct IMPA code is not confirmed
Ø48 mm48797.00776.00878.001180.001280.001250.001350.001320.001430.001386.001499.001527.831652.24A direct IMPA code is not confirmed
Ø50 mm50865.00843.00953.001280.001390.001360.001470.001440.001550.001504.001626.001657.801792.80A direct IMPA code is not confirmed
Ø52 mm52936.00911.001030.001390.001500.001470.001590.001550.001680.001627.001759.001793.081939.09A direct IMPA code is not confirmed
Ø54 mm541010.00983.001110.001500.001620.001580.001710.001670.001810.001754.001897.001933.662091.12A direct IMPA code is not confirmed
Ø56 mm561090.001060.001190.001610.001740.001700.001840.001800.001950.001887.002040.002079.542248.89A direct IMPA code is not confirmed

Include with your enquiry

  • Application, lifting arrangement, WLL and required safety factor
  • Material, coating, rope construction and connection design
  • Length, diameter, termination, markings and supporting documents

Request an offer

The specification, documents and supply terms are agreed for your enquiry. Supplier stock, lead time and price are confirmed in a separate offer.