ХАЛЛ ГРУПП · Equipment catalogue
Steel wire ropes 6×7 and 6×9W
Constructions: 6×7+FC; 6×7+IWS; 6×9W+FC; 6×9W+IWRC. The table lists diameters, approximate weights and minimum breaking loads by tensile-strength grade.
Photographs and drawings

Technical parameters
Constructions: 6×7+FC; 6×7+IWS; 6×9W+FC; 6×9W+IWRC. The table lists diameters, approximate weights and minimum breaking loads by tensile-strength grade.
A diameter row is not a fully specified configuration. Select core and tensile-strength grade from the applicable table columns. Specify construction, core, tensile grade, finish, lay, diameter tolerance and length when ordering. NF denotes natural fibre core, SF synthetic fibre core; FC fibre core and IWRC/IWS steel core follow the table notation. MBL is minimum breaking load, not working load limit. Lifting and special applications require selection calculations and documentation for the supplied configuration.
Scroll the table horizontally. Each diameter row still requires selection of the core and tensile-strength grade.
| Configuration | Diameter mm | Weight, natural NF kg/100m | Weight, synthetic SF kg/100m | Weight, IWRC/IWS kg/100m | MBL FC, 1670 MPa kN | MBL IWRC/IWS, 1670 MPa kN | MBL FC, 1770 MPa kN | MBL IWRC/IWS, 1770 MPa kN | MBL FC, 1870 MPa kN | MBL IWRC/IWS, 1870 MPa kN | MBL FC, 1960 MPa kN | MBL IWRC/IWS, 1960 MPa kN | MBL FC, 2160 MPa kN | MBL IWRC/IWS, 2160 MPa kN | IMPA correspondence |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Ø1.2 mm | 1.2 | 0.505 | 0.495 | 0.557 | 0.8 | 0.86 | 0.84 | 0.91 | 0.89 | 0.96 | 0.94 | 1 | 1.03 | 1.12 | A direct IMPA code is not confirmed |
| Ø2 mm | 2 | 1.4 | 1.38 | 1.55 | 2.21 | 2.39 | 2.35 | 2.54 | 2.48 | 2.68 | 2.6 | 2.81 | 2.87 | 3.10 | A direct IMPA code is not confirmed |
| Ø3 mm | 3 | 3.16 | 3.1 | 3.48 | 4.98 | 5.39 | 5.28 | 5.71 | 5.58 | 6.04 | 5.85 | 6.33 | 6.45 | 6.98 | A direct IMPA code is not confirmed |
| Ø4 mm | 4 | 5.62 | 5.5 | 6.19 | 8.87 | 9.59 | 9.4 | 10.1 | 9.93 | 10.7 | 10.4 | 11.2 | 11.5 | 12.4 | A direct IMPA code is not confirmed |
| Ø5 mm | 5 | 8.77 | 8.6 | 9.68 | 13.8 | 14.9 | 14.6 | 15.8 | 15.5 | 16.7 | 16.2 | 17.6 | 17.9 | 19.4 | A direct IMPA code is not confirmed |
| Ø6 mm | 6 | 12.6 | 12.4 | 13.9 | 19.9 | 21.5 | 21.1 | 22.8 | 22.3 | 24.1 | 23.4 | 25.3 | 25.8 | 27.9 | 212001 Execution requires verification 6×7 · Ø6 mm · 200 m coil Matching conditionsThe base construction 6×7 and nominal diameter 6 mm match; OEM table constructions: 6×7+FC, 6×7+IWS. IMPA 212001 specifies galvanized steel and a 200 m coil. The OEM row does not establish finish or coil length; galvanized execution and 200 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement. |
| Ø7 mm | 7 | 17.2 | 16.9 | 19 | 27.1 | 29.3 | 28.7 | 31.1 | 30.4 | 32.8 | 31.8 | 34.4 | 35.1 | 38.0 | A direct IMPA code is not confirmed |
| Ø8 mm | 8 | 22.5 | 22 | 24.8 | 35.4 | 38.3 | 37.6 | 40.6 | 39.7 | 42.9 | 41.6 | 45 | 45.9 | 49.6 | 212003 Execution requires verification 6×7 · Ø8 mm · 200 m coil Matching conditionsThe base construction 6×7 and nominal diameter 8 mm match; OEM table constructions: 6×7+FC, 6×7+IWS. IMPA 212003 specifies galvanized steel and a 200 m coil. The OEM row does not establish finish or coil length; galvanized execution and 200 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement. |
| Ø9 mm | 9 | 28.4 | 27.9 | 31.3 | 44.9 | 48.5 | 47.5 | 51.4 | 50.2 | 54.3 | 52.7 | 56.9 | 58.1 | 62.8 | 212004 Execution requires verification 6×7 · Ø9 mm · 200 m coil Matching conditionsThe base construction 6×7 and nominal diameter 9 mm match; OEM table constructions: 6×7+FC, 6×7+IWS. IMPA 212004 specifies galvanized steel and a 200 m coil. The OEM row does not establish finish or coil length; galvanized execution and 200 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement. |
| Ø10 mm | 10 | 35.1 | 34.4 | 38.7 | 55.4 | 59.9 | 58.7 | 63.5 | 62 | 67.1 | 65 | 70.3 | 71.7 | 77.5 | 212005 Execution requires verification 6×7 · Ø10 mm · 200 m coil Matching conditionsThe base construction 6×7 and nominal diameter 10 mm match; OEM table constructions: 6×7+FC, 6×7+IWS. IMPA 212005 specifies galvanized steel and a 200 m coil. The OEM row does not establish finish or coil length; galvanized execution and 200 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement. |
| Ø11 mm | 11 | 42.5 | 41.6 | 46.8 | 67 | 72.5 | 71.1 | 76.8 | 75.1 | 81.2 | 78.7 | 85.1 | 86.8 | 93.8 | A direct IMPA code is not confirmed |
| Ø12 mm | 12 | 50.5 | 49.5 | 55.7 | 79.8 | 86.3 | 84.6 | 91.5 | 89.4 | 96.6 | 93.7 | 101 | 103 | 112 | 212007 Execution requires verification 6×7 · Ø12 mm · 200 m coil Matching conditionsThe base construction 6×7 and nominal diameter 12 mm match; OEM table constructions: 6×7+FC, 6×7+IWS. IMPA 212007 specifies galvanized steel and a 200 m coil. The OEM row does not establish finish or coil length; galvanized execution and 200 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement. |
| Ø13 mm | 13 | 59.3 | 58.1 | 65.4 | 93.7 | 101 | 99.3 | 107 | 104 | 113 | 110 | 118 | 121 | 131 | A direct IMPA code is not confirmed |
| Ø14 mm | 14 | 68.8 | 67.4 | 75.9 | 108 | 117 | 115 | 124 | 121 | 131 | 127 | 138 | 141 | 152 | 212009 Execution requires verification 6×7 · Ø14 mm · 200 m coil Matching conditionsThe base construction 6×7 and nominal diameter 14 mm match; OEM table constructions: 6×7+FC, 6×7+IWS. IMPA 212009 specifies galvanized steel and a 200 m coil. The OEM row does not establish finish or coil length; galvanized execution and 200 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement. |
| Ø16 mm | 16 | 89.9 | 88.1 | 99.1 | 141 | 153 | 150 | 162 | 158 | 171 | 166 | 180 | 184 | 199 | 212010 Execution requires verification 6×7 · Ø16 mm · 200 m coil Matching conditionsThe base construction 6×7 and nominal diameter 16 mm match; OEM table constructions: 6×7+FC, 6×7+IWS. IMPA 212010 specifies galvanized steel and a 200 m coil. The OEM row does not establish finish or coil length; galvanized execution and 200 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement. |
| Ø18 mm | 18 | 114 | 111 | 125 | 179 | 194 | 190 | 205 | 201 | 217 | 210 | 228 | 232 | 251 | 212011 Execution requires verification 6×7 · Ø18 mm · 200 m coil Matching conditionsThe base construction 6×7 and nominal diameter 18 mm match; OEM table constructions: 6×7+FC, 6×7+IWS. IMPA 212011 specifies galvanized steel and a 200 m coil. The OEM row does not establish finish or coil length; galvanized execution and 200 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement. |
| Ø20 mm | 20 | 140 | 138 | 155 | 221 | 239 | 235 | 254 | 248 | 268 | 260 | 281 | 287 | 310 | 212012 Execution requires verification 6×7 · Ø20 mm · 200 m coil Matching conditionsThe base construction 6×7 and nominal diameter 20 mm match; OEM table constructions: 6×7+FC, 6×7+IWS. IMPA 212012 specifies galvanized steel and a 200 m coil. The OEM row does not establish finish or coil length; galvanized execution and 200 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement. |
| Ø22 mm | 22 | 170 | 166 | 187 | 268 | 290 | 284 | 307 | 300 | 324 | 315 | 340 | 347 | 375 | 212013 Execution requires verification 6×7 · Ø22 mm · 200 m coil Matching conditionsThe base construction 6×7 and nominal diameter 22 mm match; OEM table constructions: 6×7+FC, 6×7+IWS. IMPA 212013 specifies galvanized steel and a 200 m coil. The OEM row does not establish finish or coil length; galvanized execution and 200 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement. |
| Ø24 mm | 24 | 202 | 198 | 223 | 319 | 345 | 338 | 366 | 357 | 386 | 374 | 405 | 413 | 447 | 212015 Execution requires verification 6×7 · Ø24 mm · 200 m coil Matching conditionsThe base construction 6×7 and nominal diameter 24 mm match; OEM table constructions: 6×7+FC, 6×7+IWS. IMPA 212015 specifies galvanized steel and a 200 m coil. The OEM row does not establish finish or coil length; galvanized execution and 200 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement. |
| Ø26 mm | 26 | 237 | 233 | 262 | 371 | 405 | 397 | 429 | 419 | 453 | 440 | 475 | 485 | 524 | 212017 Execution requires verification 6×7 · Ø26 mm · 200 m coil Matching conditionsThe base construction 6×7 and nominal diameter 26 mm match; OEM table constructions: 6×7+FC, 6×7+IWS. IMPA 212017 specifies galvanized steel and a 200 m coil. The OEM row does not establish finish or coil length; galvanized execution and 200 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement. |
| Ø28 mm | 28 | 275 | 270 | 303 | 434 | 470 | 460 | 498 | 486 | 526 | 510 | 551 | 562 | 608 | 212018 Execution requires verification 6×7 · Ø28 mm · 200 m coil Matching conditionsThe base construction 6×7 and nominal diameter 28 mm match; OEM table constructions: 6×7+FC, 6×7+IWS. IMPA 212018 specifies galvanized steel and a 200 m coil. The OEM row does not establish finish or coil length; galvanized execution and 200 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement. |
| Ø30 mm | 30 | 316 | 310 | 348 | 498 | 539 | 528 | 571 | 558 | 604 | 585 | 633 | 645 | 698 | 212019 Execution requires verification 6×7 · Ø30 mm · 200 m coil Matching conditionsThe base construction 6×7 and nominal diameter 30 mm match; OEM table constructions: 6×7+FC, 6×7+IWS. IMPA 212019 specifies galvanized steel and a 200 m coil. The OEM row does not establish finish or coil length; galvanized execution and 200 m length still require confirmation. Select and confirm the required FC / IWS / IWRC core separately. Tensile grade (MPa), breaking force, working load limit, lay and documents must be agreed for the offered execution. This is a selection candidate, not a confirmed replacement. |
Include with your enquiry
- Application, lifting arrangement, WLL and required safety factor
- Material, coating, rope construction and connection design
- Length, diameter, termination, markings and supporting documents
Related sections
Request an offer
The specification, documents and supply terms are agreed for your enquiry. Supplier stock, lead time and price are confirmed in a separate offer.